Detection rules › Sigma

DHCP Server Loaded the CallOut DLL

Severity
high
Author
Dimitrios Slamaris
Source
upstream

This rule detects a DHCP server in which a specified Callout DLL (in registry) was loaded

MITRE ATT&CK coverage

TacticTechniques
PersistenceT1574.001 Hijack Execution Flow: DLL
Privilege EscalationT1574.001 Hijack Execution Flow: DLL
Defense EvasionT1574.001 Hijack Execution Flow: DLL

Event coverage

ProviderEvent IDTitle
DHCP-Server1033[EVENT_SERVER_CALLOUT_LOAD_SUCCESS] The DHCP service has successfully loaded one or more callout DLLs.

Stages and Predicates

Stage 1: selection

Provider_Name: Microsoft-Windows-DHCP-Server

Indicators

Each row is a field, operator, and value that the rule matches. The corpus column counts how many other rules in the catalog look for the same combination: high numbers point to widely-used, community-vetted indicators. Blank or 1 shows that the indicator is specific to this rule.

FieldKindValues
Provider_Nameeq
  • Microsoft-Windows-DHCP-Server corpus 2 (sigma 2)