Microsoft-Windows-Time-Service-PTP-Provider

12 events across 1 channel

Event ID 512 — PTP provider started receiving announcements from the PTP Master %1 with IP Address %2 on local IfIndex:%15 and the following PTP parameters: Clock...

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider started receiving announcements from the PTP Master %1 with IP Address %2 on local IfIndex:%15 and the following PTP parameters:
Clock Identity:%3
Port Number:%4
Domain Number:%5
Utc Offset Valid:%6
Current UTC Offset:%7
Flags:%8
Grandmaster Clock Id:%9
Steps Removed From GM:%10
Time Source Code:%11
Announce Interval (Log2):%12

Number of active Masters:%13
Current Tick Count:%14
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
Name
Address
MasterClockId
MasterPortNum
DomainNumber
UTCValid
CurrentUTCOffset
Flags
GrandMasterClockId
StepsRemovedFromGrandMaster
TimeSourceCode
LogAnnounceInterval
ActiveMasterCount
TickCount
LocalIfIndex

Event ID 513 — PTP provider has chosen the PTP Master %1 with IP Address %2 on local IfIndex:%14 as the best master and the source of time.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider has chosen the PTP Master %1 with IP Address %2 on local IfIndex:%14 as the best master and the source of time. This master is announcing the following PTP parameters:
Clock Identity:%3
Port Number:%4
Domain Number:%5
Utc Offset Valid:%6
Current UTC Offset:%7
Flags:%8
Grandmaster Clock Id:%9
Steps Removed From GM:%10
Time Source Code:%11
Announce Interval (Log2):%12

Current Tick Count:%13
If the best master keeps changing frequently, verify that the masters and this client have the same announce interval configured. For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
BestMasterName
MasterAddress
MasterClockId
MasterPortNum
DomainNumber
UTCValid
CurrentUTCOffset
Flags
GrandMasterClockId
StepsRemovedFromGrandMaster
TimeSourceCode
LogAnnounceInterval
TickCount
LocalIfIndex

Event ID 514 — PTP Master %1 with IP Address %2 has made no announcements in the last announce timeout window (%3 milliseconds).

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP Master %1 with IP Address %2 has made no announcements in the last announce timeout window (%3 milliseconds). It is excluded from being considered as a (potential) time source. PTP Master parameters:
Clock Identity:%4
Port Number:%5
Domain Number:%9
Announce Interval (Log2):%6

Number of active Masters:%7
Current Tick Count:%8
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
Name
Address
AnnounceTimeoutMsec
MasterClockId
MasterPortNum
LogAnnounceInterval
ActiveMasterCount
TickCount
DomainNumber

Event ID 515 — Ptp Provider Configuration: Allowed Masters:%1 Allow Any Master:%17 Local Domain Number:%18 Announce Interval:%2(msec) Delay Poll Interval:%3(msec)...

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

Ptp Provider Configuration:

Allowed Masters:%1
Allow Any Master:%17
Local Domain Number:%18
Announce Interval:%2(msec)
Delay Poll Interval:%3(msec)
Timestamping Allowed:%4
Multicast Rx Enabled:%11
PTP E2E Correction Enabled:%13
HW TSTMP IfIndex:%14
Multicast-Only Tx Enabled:%15
Multicast IfIndex:%16
(IfIndex: 0 = none chosen, (1, ULONG_MAX) = specific interface, ULONG_MAX = all available)
PTP provider status:

PTP Best Master Details:
Name:%5
IP Address:%6
Clock Identity:%7
Port Number:%8
Domain number:%19
Tick Count At Last Time Sample:%9

ActiveMasterCount:%10
Current Tick Count:%12
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
AllowedMastersList
AnnounceIntervalMsec
DelayPollIntervalMsec
IfTstmp
BestMasterName
BMAddress
BMClockId
BMPortNum
BMLastTimeSampleTickCount
ActiveMasterCount
MulticastRxEnabled
TickCount
E2ECorrectionEnabled
HWTstmpingIfIndex
MulticastOnlyTxEnabled
MulticastIfIndex
AllowAnyMaster
LocalDomainNumber
MasterDomainNumber

Event ID 516 — Messages from PTP Master will be ignored because the master is not allowed.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

Messages from PTP Master will be ignored because the master is not allowed.
PTP Master parameters:
IP Address:%1
Clock Identity:%2
Port Number:%3
Domain Number:%4
Utc Offset Valid:%5
Current UTC Offset:%6
Flags:%7
Grandmaster Clock Id:%8
Steps Removed From GM:%9
Time Source Code:%10
Announce Interval (Log2):%11

Number of active Masters:%12
Current Tick Count:%13
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
Address
MasterClockId
MasterPortNum
DomainNumber
UTCValid
CurrentUTCOffset
Flags
GrandMasterClockId
StepsRemovedFromGrandMaster
TimeSourceCode
LogAnnounceInterval
ActiveMasterCount
TickCount

Event ID 517 — PTP provider has detected the following timestamping capabilities (IF_INDEX values printed): Hardware timestamping available on network interfaces:...

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider has detected the following timestamping capabilities (IF_INDEX values printed):
Hardware timestamping available on network interfaces:%1
Software timestamping available on network interfaces:%2
Ambiguous timestamp settings on network interfaces:%3
No timestamping available on network interfaces:%4
Current Tick Count:%2
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
IfIndexList
SWTSIfIndexList
AmbiguousTSIfIndexList
NoTSIfIndexList
TickCount

Event ID 518 — PTP provider can translate hardware timestamps from the NIC with IfIndex %1 Current Tick Count:%2 For more information, see https://go.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider can translate hardware timestamps from the NIC with IfIndex %1
Current Tick Count:%2
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
IfIndex
TickCount

Event ID 519 — PTP provider is unable to translate hardware timestamps from the NIC with IfIndex %1 Current Tick Count:%2 For more information, see https://go.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider is unable to translate hardware timestamps from the NIC with IfIndex %1
Current Tick Count:%2
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
IfIndex
TickCount

Event ID 520 — PTP provider is configured to accept announcements from any master on the network.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider is configured to accept announcements from any master on the network. Ensure that this setting is intentional. This message will repeat periodically.
Number of active Masters:%1
Current Tick Count:%2
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
ActiveMasterCount
TickCount

Event ID 521 — PTP provider is receiving timestamps from the network stack.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider is receiving timestamps from the network stack. These typically help reduce the jitter in time error calculations and improve time sync accuracy.Some timestamps need to be translated before use. Look for other events for more information on timestamp translation. 
Current Tick Count:%1
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
TickCount

Event ID 522 — PTP provider is not receiving any timestamps from the network stack, which may result in lowered time sync accuracy.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

PTP provider is not receiving any timestamps from the network stack, which may result in lowered time sync accuracy. This is the default configuration and the behavior on service startup. This can also occur if there are conflicting settings for a NIC or due to actual runtime issues.
Current Tick Count:%1
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
TickCount

Event ID 523 — The timestamp settings on the NICs in this system are ambiguous, with a combination of different kinds of timestamping enabled.

Provider
Microsoft-Windows-Time-Service-PTP-Provider
Channel
PTP-Operational

Message

The timestamp settings on the NICs in this system are ambiguous, with a combination of different kinds of timestamping enabled. The resulting timestamps may not be translated correctly, resulting in sub-optimal time sync accuracy. There could also be path asymmetry due to the use of different kinds of timestamp types on different NICs in the system. For best results, enable a single kind of timestamping on all NICs in the system.
Current Tick Count:%1
For more information, see https://go.microsoft.com/fwlink/?linkid=873491.

Fields

NameDescription
TickCount