Microsoft-Windows-SPB-ClassExtension

19 events across 2 channels

Event ID 1000 — The Simple Peripheral Bus WDF class extension has started.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

The Simple Peripheral Bus WDF class extension has started.  The control object name is %1.

Fields

NameDescription
ControlDeviceName
Status

Event ID 1001 — The Simple Peripheral Bus WDF class extension failed to start (error %2).

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

The Simple Peripheral Bus WDF class extension failed to start (error %2).  The control object name is %1.

Fields

NameDescription
ControlDeviceName
Status

Event ID 1002 — The Simple Peripheral Bus WDF class extension has unloaded.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

The Simple Peripheral Bus WDF class extension has unloaded.

Event ID 1010 —

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Fields

NameDescription
Controller
TargetName
ScopeTag
File
Request
RequestType
Length

Event ID 1011 —

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Event ID 1012 —

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Event ID 1013 —

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Event ID 1014 —

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Event ID 1015 —

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Fields

NameDescription
Request
CompletionStatus
Information

Event ID 1016 —

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Event ID 1017 — Data: {Data}.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Data: {Data}

Fields

NameDescription
Data

Event ID 1018 — Direction.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Direction: %1

Fields

NameDescription
Data

Event ID 1019 — Target %2 has exceeded the locked IO watchdog period.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Target %2 has exceeded the locked IO watchdog period.

Fields

NameDescription
Controller
TargetName
ScopeTag
File

Event ID 1020 — Preprocessing %2 IRP in SPBCx for controller %1.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Preprocessing %2 IRP in SPBCx for controller %1.

Fields

NameDescription
Controller
DeviceState

Event ID 1021 — Payload begin: TotalByteCount = %1, TransferCount = %2.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Payload begin: TotalByteCount = %1, TransferCount = %2

Fields

NameDescription
IoTotalByteCount
TransferCount

Event ID 1022 — Transfer descriptor begin: Index = %1, Direction = %2, TotalByteCount = %3.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Transfer descriptor begin: Index = %1, Direction = %2, TotalByteCount = %3

Fields

NameDescription
TransferIndex
TransferDirection
TransferTotalByteCount

Event ID 1023 — Transfer buffer: Index = %1, ByteCount = %2.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Transfer buffer: Index = %1, ByteCount = %2

Fields

NameDescription
BufferIndex
ByteCount
Buffer

Event ID 1024 — Transfer descriptor end.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Transfer descriptor end.

Event ID 1025 — Payload end.

Provider
Microsoft-Windows-SPB-ClassExtension
Channel
Analytic

Message

Payload end.