Microsoft-Windows-Hyper-V-EmulatedNic
38 events across 3 channels
| Event ID | Title | Channel |
|---|---|---|
| 1 | Operational | |
| 1 | [VMID VmId] TraceData. | Microsoft-Windows-Hyper-V-Worker-Analytic |
| 2 | Operational | |
| 2 | [VMID VmId] TraceData. | Microsoft-Windows-Hyper-V-Worker-Analytic |
| 3 | Operational | |
| 3 | [VMID VmId] TraceData. | Microsoft-Windows-Hyper-V-Worker-Analytic |
| 4 | Operational | |
| 4 | [VMID VmId] TraceData. | Microsoft-Windows-Hyper-V-Worker-Analytic |
| 12440 | Operational | |
| 12440 | 'VmName' error 'ErrorCodeString' (ErrorCode) while opening file 'String' during … | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12530 | Operational | |
| 12530 | 'VmName' device Device could not allocate guest physical address space. | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12531 | Operational | |
| 12531 | Device Device could not allocate guest physical address space. | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12560 | Operational | |
| 12560 | 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) is invalid. | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12562 | Operational | |
| 12562 | 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) conflicts with … | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12564 | Operational | |
| 12564 | 'VmName' No available MAC address for "NicName". | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12572 | Operational | |
| 12572 | '. | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12580 | Operational | |
| 12580 | 'VmName' Dynamic MAC address MacAddress for NicName (NicGuid) is invalid. | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12581 | Operational | |
| 12581 | Dynamic MAC address MacAddress for NicName (NicGuid) is invalid. | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12670 | Operational | |
| 12670 | 'VmName' failed to allocate a connection to a virtual network: ErrorCodeString … | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12671 | Operational | |
| 12671 | Failed to allocate resources while connecting to a virtual network. | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12672 | Operational | |
| 12672 | The virtual machine VmName cannot load device Device because there are no … | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12673 | Operational | |
| 12673 | The device Device cannot be loaded because there are no mutually support … | Microsoft-Windows-Hyper-V-Worker-Admin |
| 12692 | Operational | |
| 12692 | Bytes sent or received by 'VmName' is larger than what can fit inside of a … | Microsoft-Windows-Hyper-V-Worker-Admin |
| 33010 | Operational | |
| 33010 | Could not find an Ethernet connection resource pool with ID 'Parameter0'. | Microsoft-Windows-Hyper-V-Worker-Admin |
Event ID 1 —
Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | — |
VmName UnicodeString | — |
VmId UnicodeString | — |
StackFrameCount UInt32 | — |
StackFrame Pointer | — |
ModuleCount UInt32 | — |
Module Int32 | — |
Event ID 1 — [VMID VmId] TraceData.
Event ID 2 —
Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | — |
VmName UnicodeString | — |
VmId UnicodeString | — |
StackFrameCount UInt32 | — |
StackFrame Pointer | — |
ModuleCount UInt32 | — |
Module Int32 | — |
Event ID 2 — [VMID VmId] TraceData.
Event ID 3 —
Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | — |
VmName UnicodeString | — |
VmId UnicodeString | — |
StackFrameCount UInt32 | — |
StackFrame Pointer | — |
ModuleCount UInt32 | — |
Module Int32 | — |
Event ID 3 — [VMID VmId] TraceData.
Event ID 4 —
Fields #
| Name | Description |
|---|---|
TraceData UnicodeString | — |
VmName UnicodeString | — |
VmId UnicodeString | — |
StackFrameCount UInt32 | — |
StackFrame Pointer | — |
ModuleCount UInt32 | — |
Module Int32 | — |
Event ID 4 — [VMID VmId] TraceData.
Event ID 12440 —
Description
'VmName' error 'ErrorCodeString' (ErrorCode) while opening file 'String' during ethernet device startup. The Hyper-V network service provider may not be installed. (Virtual machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
String UnicodeString | — |
ErrorCodeString UnicodeString | — |
ErrorCode UnicodeString | — |
Param1 UnicodeString | — |
Param2 UnicodeString | — |
Event ID 12440 — 'VmName' error 'ErrorCodeString' (ErrorCode) while opening file 'String' during ethernet device startup.
Description
'VmName' error 'ErrorCodeString' (ErrorCode) while opening file 'String' during ethernet device startup. The Hyper-V network service provider may not be installed. (Virtual machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
String UnicodeString | — |
ErrorCodeString UnicodeString | — |
ErrorCode UnicodeString | — |
Param1 UnicodeString | — |
Param2 UnicodeString | — |
Event ID 12530 —
Description
'VmName' device Device could not allocate guest physical address space. (Virtual machine ID VmId).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
Device UnicodeString | — |
Event ID 12530 — 'VmName' device Device could not allocate guest physical address space.
Event ID 12531 —
Description
Device could not allocate guest physical address space.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
Device UnicodeString | — |
Event ID 12531 — Device Device could not allocate guest physical address space.
Event ID 12560 —
Description
'VmName' Static MAC address MacAddress for "NicName" (NicGuid) is invalid.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
NicGuid UnicodeString | — |
NicName UnicodeString | — |
MacAddress UnicodeString | — |
Event ID 12560 — 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) is invalid.
Event ID 12562 —
Description
'VmName' Static MAC address MacAddress for "NicName" (NicGuid) conflicts with another adapter.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
NicGuid UnicodeString | — |
NicName UnicodeString | — |
MacAddress UnicodeString | — |
Event ID 12562 — 'VmName' Static MAC address MacAddress for "NicName" (NicGuid) conflicts with another adapter.
Event ID 12564 —
Description
'VmName' No available MAC address for "NicName".
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
NicGuid UnicodeString | — |
NicName UnicodeString | — |
Event ID 12564 — 'VmName' No available MAC address for "NicName".
Event ID 12572 —
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
NicGuid UnicodeString | — |
NicName UnicodeString | — |
MacAddress UnicodeString | — |
Event ID 12572 — '.
Event ID 12580 —
Description
'VmName' Dynamic MAC address MacAddress for NicName (NicGuid) is invalid.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
NicGuid UnicodeString | — |
NicName UnicodeString | — |
MacAddress UnicodeString | — |
Event ID 12580 — 'VmName' Dynamic MAC address MacAddress for NicName (NicGuid) is invalid.
Event ID 12581 —
Description
Dynamic MAC address for () is invalid.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
NicGuid UnicodeString | — |
NicName UnicodeString | — |
MacAddress UnicodeString | — |
Event ID 12581 — Dynamic MAC address MacAddress for NicName (NicGuid) is invalid.
Event ID 12670 —
Description
'VmName' failed to allocate a connection to a virtual network: ErrorCodeString (ErrorCode) (Virtual Machine ID VmId). The Ethernet switch may not exist.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
String UnicodeString | — |
ErrorCodeString UnicodeString | — |
ErrorCode UnicodeString | — |
Param1 UnicodeString | — |
Param2 UnicodeString | — |
Event ID 12670 — 'VmName' failed to allocate a connection to a virtual network: ErrorCodeString (ErrorCode) (Virtual Machine ID VmId).
Description
'VmName' failed to allocate a connection to a virtual network: ErrorCodeString (ErrorCode) (Virtual Machine ID VmId). The Ethernet switch may not exist.
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
String UnicodeString | — |
ErrorCodeString UnicodeString | — |
ErrorCode UnicodeString | — |
Param1 UnicodeString | — |
Param2 UnicodeString | — |
Event ID 12671 —
Description
Failed to allocate resources while connecting to a virtual network. The Ethernet switch may not exist.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
String UnicodeString | — |
ErrorCodeString UnicodeString | — |
ErrorCode UnicodeString | — |
Param1 UnicodeString | — |
Param2 UnicodeString | — |
Event ID 12671 — Failed to allocate resources while connecting to a virtual network.
Description
Failed to allocate resources while connecting to a virtual network. The Ethernet switch may not exist.
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
String UnicodeString | — |
ErrorCodeString UnicodeString | — |
ErrorCode UnicodeString | — |
Param1 UnicodeString | — |
Param2 UnicodeString | — |
Event ID 12672 —
Description
The virtual machine cannot load device because there are no mutually supported protocol versions. The server version is and the client version is (Virtual machine ID ).
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
Device UnicodeString | — |
ServerVersion UnicodeString | — |
ClientVersion UnicodeString | — |
Event ID 12672 — The virtual machine VmName cannot load device Device because there are no mutually supported protocol versions.
Description
The virtual machine VmName cannot load device Device because there are no mutually supported protocol versions. The server version is ServerVersion and the client version is ClientVersion (Virtual machine ID VmId).
Message #
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
Device UnicodeString | — |
ServerVersion UnicodeString | — |
ClientVersion UnicodeString | — |
Event ID 12673 —
Description
The device cannot be loaded because there are no mutually support protocol versions between the server and client.
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
Device UnicodeString | — |
ServerVersion UnicodeString | — |
ClientVersion UnicodeString | — |
Event ID 12673 — The device Device cannot be loaded because there are no mutually support protocol versions between the server and client.
Event ID 12692 —
Fields #
| Name | Description |
|---|---|
VmName UnicodeString | — |
VmId UnicodeString | — |
String UnicodeString | — |
ErrorCodeString UnicodeString | — |
ErrorCode UnicodeString | — |
Param1 UnicodeString | — |
Param2 UnicodeString | — |
Event ID 12692 — Bytes sent or received by 'VmName' is larger than what can fit inside of a 64-bit integer.
Event ID 33010 —
Description
Could not find an Ethernet connection resource pool with ID 'Parameter0'.
Fields #
| Name | Description |
|---|---|
Parameter0 UnicodeString | — |