Microsoft-Windows-Host-Network-Management

12 events across 2 channels

EventTitleChannel
1000Event ID 1000Operational
1000A reboot is required to complete switch creation.Microsoft-Windows-Host-Network-Service-Admin
1001Event ID 1001Operational
1001Virtual Switch Extension could not be deleted, name='Parameter0', friendly …Microsoft-Windows-Host-Network-Service-Admin
1002Event ID 1002Operational
1002Internal miniport deleted, name = 'Parameter0', friendly name = 'Parameter1'.Microsoft-Windows-Host-Network-Service-Admin
1003Event ID 1003Operational
1003Ethernet switch port disconnected (switch name = 'Parameter0', port name = …Microsoft-Windows-Host-Network-Service-Admin
1004Event ID 1004Operational
1004A reboot is required before the internal ethernet port 'Parameter0' will be …Microsoft-Windows-Host-Network-Service-Admin
1005Event ID 1005Operational
1005Action taken to remove orphaned component: 'Action' 'Name' ('Detail'), …Microsoft-Windows-Host-Network-Service-Admin

Event ID 1000:

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Operational

Description

A reboot is required to complete switch creation. The data path will not be active until reboot. name = 'Parameter0', friendly name = 'Parameter1'.

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1000: A reboot is required to complete switch creation.

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Microsoft-Windows-Host-Network-Service-Admin

Description

A reboot is required to complete switch creation. The data path will not be active until reboot. name = 'Parameter0', friendly name = 'Parameter1'.

Message #

A reboot is required to complete switch creation. The data path will not be active until reboot. name = '%1', friendly name = '%2'.

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1001:

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Operational

Description

Virtual Switch Extension could not be deleted, name='Parameter0', friendly name='Parameter1': ErrorMessage (ErrorCode).

Fields #

NameDescription
ErrorMessage UnicodeString
ErrorCode UnicodeString
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1001: Virtual Switch Extension could not be deleted, name='Parameter0', friendly name='Parameter1': ErrorMessage (ErrorCode).

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Microsoft-Windows-Host-Network-Service-Admin

Description

Virtual Switch Extension could not be deleted, name='Parameter0', friendly name='Parameter1': ErrorMessage (ErrorCode).

Message #

Virtual Switch Extension could not be deleted, name='%3', friendly name='%4': %1 (%2).

Fields #

NameDescription
ErrorMessage UnicodeString
ErrorCode UnicodeString
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1002:

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Operational

Description

Internal miniport deleted, name = 'Parameter0', friendly name = 'Parameter1'.

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1002: Internal miniport deleted, name = 'Parameter0', friendly name = 'Parameter1'.

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Microsoft-Windows-Host-Network-Service-Admin

Description

Internal miniport deleted, name = 'Parameter0', friendly name = 'Parameter1'.

Message #

Internal miniport deleted, name = '%1', friendly name = '%2'.

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1003:

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Operational

Description

Ethernet switch port disconnected (switch name = 'Parameter0', port name = 'Parameter1').

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1003: Ethernet switch port disconnected (switch name = 'Parameter0', port name = 'Parameter1').

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Microsoft-Windows-Host-Network-Service-Admin

Description

Ethernet switch port disconnected (switch name = 'Parameter0', port name = 'Parameter1').

Message #

Ethernet switch port disconnected (switch name = '%1', port name = '%2').

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1004:

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Operational

Description

A reboot is required before the internal ethernet port 'Parameter0' will be usable.

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1004: A reboot is required before the internal ethernet port 'Parameter0' will be usable.

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Microsoft-Windows-Host-Network-Service-Admin

Description

A reboot is required before the internal ethernet port 'Parameter0' will be usable.

Message #

A reboot is required before the internal ethernet port '%1' will be usable.

Fields #

NameDescription
Parameter0 UnicodeString
Parameter1 UnicodeString

Event ID 1005:

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Operational

Description

Action taken to remove orphaned component: 'Action' 'Name' ('Detail'), result='Result'.

Fields #

NameDescription
Action UnicodeString
Name UnicodeString
Detail UnicodeString
Result HexInt32

Event ID 1005: Action taken to remove orphaned component: 'Action' 'Name' ('Detail'), result='Result'.

#
Provider
Microsoft-Windows-Host-Network-Management
Channel
Microsoft-Windows-Host-Network-Service-Admin

Description

Action taken to remove orphaned component: 'Action' 'Name' ('Detail'), result='Result'.

Message #

Action taken to remove orphaned component: '%1' '%2' ('%3'), result='%4'

Fields #

NameDescription
Action UnicodeString
Name UnicodeString
Detail UnicodeString
Result HexInt32

Provenance

Where this provider's schema came from, and which Windows build it was observed on. Windows can change a provider's event schema between builds, so use this to judge whether it matches the build you collect from.

ETW provider GUID 93f693dc-9163-4dee-af64-d855218af242

Defined in NetMgmtIF.dll, which carries the event manifest.

Observed on:

  • Win11-26200.6584 · schema read from the registered manifest · binary version 10.0.26100.1 · captured 2026-06-02

Downloads

Credits

  • Microsoft - authored the ETW manifests and PDBs the schema comes from
  • jdu2600 - the event-schema TSV format this catalog adopted
  • nasbench - the tool that dumps registered providers and manifests