Microsoft-Windows-ClusterAwareUpdating-Management
46 events across 2 channels
Event ID 1001: Cluster updating has exceeded the warning timeout of timeoutValue.
#Event ID 1001:
#Description
Cluster updating has exceeded the warning timeout of .
Fields #
| Name | Description |
|---|---|
timeoutValue UInt32 |
Event ID 1002: Cluster updating has exceeded the StopAfter timeout of timeoutValue.
#Event ID 1002:
#Description
Cluster updating has exceeded the StopAfter timeout of . Stopping updating run.
Fields #
| Name | Description |
|---|---|
timeoutValue UInt32 |
Event ID 1003: Starting CAU run runIdentifier on cluster clusterName.
#Event ID 1003:
#Description
Starting CAU run on cluster .
Fields #
| Name | Description |
|---|---|
runIdentifier GUID | |
clusterName UnicodeString |
Event ID 1004: CAU run runIdentifier on cluster clusterName completed successfully.
#Event ID 1004:
#Description
CAU run on cluster completed successfully.
Fields #
| Name | Description |
|---|---|
runIdentifier GUID | |
clusterName UnicodeString |
Event ID 1005: CAU run runIdentifier on cluster clusterName was canceled.
#Event ID 1005:
#Description
CAU run on cluster was canceled.
Fields #
| Name | Description |
|---|---|
runIdentifier GUID | |
clusterName UnicodeString |
Event ID 1006: CAU run runIdentifier on cluster clusterName failed partially.
#Event ID 1006:
#Description
CAU run on cluster failed partially.
Fields #
| Name | Description |
|---|---|
runIdentifier GUID | |
clusterName UnicodeString |
Event ID 1007: CAU run runIdentifier on cluster clusterName failed.
#Event ID 1007:
#Description
CAU run on cluster failed. Error Message: Error Code: Stack.
Fields #
| Name | Description |
|---|---|
runIdentifier GUID | |
clusterName UnicodeString | |
errorMessage UnicodeString | |
errorCode Int32 | |
stackTrace UnicodeString |
Event ID 1008: Node clusterNodeName entered node maintenance mode.
#Event ID 1008:
#Description
Node entered node maintenance mode.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString |
Event ID 1009: Node clusterNodeName exited node maintenance mode.
#Event ID 1009:
#Description
Node exited node maintenance mode.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString |
Event ID 1010: Rebooting node clusterNodeName.
#Event ID 1011: Node clusterNodeName has rebooted successfully.
#Event ID 1011:
#Description
Node has rebooted successfully.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString |
Event ID 1012: Failed to reboot node clusterNodeName.
#Event ID 1012:
#Description
Failed to reboot node . Details.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString | |
errorMessage UnicodeString |
Event ID 1013: CAU run failed on node clusterNodeName.
#Event ID 1013:
#Description
CAU run failed on node . Details.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString | |
errorMessage UnicodeString |
Event ID 1014: Recovering the cluster clusterName from previous CAU run.
#Event ID 1014:
#Description
Recovering the cluster from previous CAU run.
Fields #
| Name | Description |
|---|---|
clusterName UnicodeString |
Event ID 1015: Failed to acquire lock on node clusterNodeName.
#Event ID 1015:
#Description
Failed to acquire lock on node . This could be due to a different instance of orchestrator that owns the lock on this node.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString |
Event ID 1016: Failed to put node clusterNodeName in node maintenance mode.
#Event ID 1016:
#Description
Failed to put node in node maintenance mode. Details.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString | |
errorMessage UnicodeString |
Event ID 1017: Failed to resume node clusterNodeName from node maintenance mode.
#Event ID 1017:
#Description
Failed to resume node from node maintenance mode. Details.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString | |
errorMessage UnicodeString |
Event ID 1018: Canceling CAU run as rebooting node clusterNodeName will compromise cluster quorum.
#Event ID 1018:
#Description
Canceling CAU run as rebooting node will compromise cluster quorum.
Fields #
| Name | Description |
|---|---|
clusterNodeName UnicodeString |
Event ID 1019: Canceling CAU run as patching failed on nodeCount (MaxFailedNodes) nodes.
#Event ID 1019:
#Description
Canceling CAU run as patching failed on (MaxFailedNodes) nodes.
Fields #
| Name | Description |
|---|---|
nodeCount Int32 |
Event ID 1020: Canceling CAU run as all nodes are required to be online.
#Event ID 1020:
#Description
Canceling CAU run as all nodes are required to be online. nodes are currently offline.
Fields #
| Name | Description |
|---|---|
nodeCount Int32 |
Event ID 1021: User canceled CAU run runIdentifier on cluster clusterName.
#Event ID 1021:
#Description
User canceled CAU run on cluster .
Fields #
| Name | Description |
|---|---|
runIdentifier GUID | |
clusterName UnicodeString |
Event ID 1022: Failed to save CAU report.
#Event ID 1022:
#Description
Failed to save CAU report. Details.
Fields #
| Name | Description |
|---|---|
errorMessage UnicodeString |
Event ID 1023: Failed to get CAU report.
#Event ID 1023:
#Description
Failed to get CAU report. Details.
Fields #
| Name | Description |
|---|---|
errorMessage UnicodeString |
Provenance
Where this provider's schema came from, and which Windows build it was observed on. Windows can change a provider's event schema between builds, so use this to judge whether it matches the build you collect from.
ETW provider GUID 9b9e93d6-5569-4179-8c8a-5201cb2b9536
Defined in ClusterAwareUpdatingNative.dll, which carries the event manifest.
Observed on:
- WS2022-20348.4893 · schema read from the registered manifest · binary version 10.0.20348.1 · captured 2026-06-02
Downloads
- Microsoft-Windows-ClusterAwareUpdating-Management registered manifest XML (WS2022-20348.4893) manifest-xml